BI01 SIS interface module

Supported Access:Modbus RTU

Baud rate:9600 bps-115200 bps

Data bit:8 bits

Stop bit:1 or 2 bits

Parity check:none,even check,odd check

Maximum number of connected devices:32

Power supply voltage:24 V DC

Power consumption:5W

Working temperature:-20°C to+85°C

Dimensions:115 mm x 65 mm x 30 mm(4.5 inches x 2.6 inches x 1.2 inches)

Category:
Contact Us WhatsApp / Wechat:+8618150087953 / +86 18005022138
Phone:+86 18150087953 / +86 18005022138
Email:sales@cxplcmro.com

Description

BI01 SIS interface module

Product Overview

BI01 is a bathroom interface module produced by SIS,used to convert general I/O signals into Modbus RTU link signals and communicate with them.It is a structured,high-performance module that provides reliable performance and flexible configuration.BI01 is suitable for various applications,including:

Industrial control

Data collection

Process monitoring

Building automation

BI01 SIS

BI01 SIS

Product parameters

Supported Access:Modbus RTU

Baud rate:9600 bps-115200 bps

Data bit:8 bits

Stop bit:1 or 2 bits

Parity check:none,even check,odd check

Maximum number of connected devices:32

Power supply voltage:24 V DC

Power consumption:5W

Working temperature:-20°C to+85°C

Dimensions:115 mm x 65 mm x 30 mm(4.5 inches x 2.6 inches x 1.2 inches)

Product specifications

Interface:RS-485

Protocol:Modbus RTU

Connector:M12 connector

Protection level:IP65

Series

BI01 belongs to the BI series bathroom interface module of SIS.The BI series is renowned for its improved interfaces,flexibility,and flexibility.

BI01 SIS

BI01 SIS

Features

Supports multiple Modbus RTU functions,including reading,filled in,reading status,etc.

Supports multi master mode and can connect multiple master devices.

Supports automatic baud rate detection and requires manual setting of the baud rate.

It has isolation function to prevent possible interference and damage.

Function

The function of BI01 is to convert universal I/O signals into Modbus RTU connection signals and communicate with them.It can convert general I/O signal devices such as sensors and instruments into Modbus RTU access signals and transmit them to the Modbus RTU main device.

Purpose

BI01 can be used for various applications,including:

Industrial control:BI01 can be used to control industrial equipment,such as motors,valves,etc.

Data collection:BI01 can be used to collect data from sensors and instruments.

Process monitoring:BI01 can be used to monitor industrial process parameters,such as temperature,pressure,etc.

Building Automation:BI01 can be used to control building automation equipment,such as lighting,air conditioning,etc.

Application field

BI01 extensively evaluates industrial automation,energy,water treatment,construction,and other industries.